MEES 2031 exposure in Canterbury

29 of the 43 industrial and warehouse buildings over 1,000 m² in Canterbury with an EPC are rated C to E: 560k sq ft (51,988 m²) of floorspace that meets today's E minimum but falls short of the proposed EPC B standard.

Free. No card needed.

Canterbury in figures

EPC register, snapshot 30 Sep 2026

Rated C to E
560k sq ft51,988 m² in 29 buildings
Rated F or G
1 building13k sq ft (1,176 m²), below today's E minimum
Rated A+ to B
13 buildingsAlready at the proposed standard
Share below B
70%Of 43 buildings over 1,000 m². England and Wales: 70%

Canterbury has the 292nd most floorspace rated C to E of 316 local authorities in England and Wales, and the 53rd most of 64 in the South East.

EPC rating mix

Share of buildings over 1,000 m², by latest EPC rating

  • Canterbury43 buildings
  • South East5,119 buildings
  • England and Wales38,148 buildings
Key: Rated A+–B: At B or better alreadyRated C–E: Meets today's E minimum, short of BRated F–G: Below today's E minimum

Latest certificate per building from the government's EPC register, snapshot 30 Sep 2026. Industrial and warehouse uses (B2 and B8), floor area over 1,000 m² as declared on the EPC; 1 m² is 10.7639 sq ft. How we count it

What stands out in Canterbury

Compared with the other 63 local authorities in the South East and with England and Wales, from the same EPC register snapshot.

  • Most of its floorspace rated C to E, 100% or 560k sq ft (51,988 m²), is in 29 buildings of 1,000 to 5,000 m².
  • 17 of its 30 buildings rated C to G (57%) have an EPC that has lapsed or is estimated to lapse before 2031, against 54% across England and Wales; 8 have already lapsed.
  • 5 of its 16 C-rated buildings (31%) have an asset rating of 51 to 60, within 10 points of band B: 93k sq ft (8,650 m²) of floorspace. Across England and Wales it's 37%.
  • General industrial (B2) makes up 56% of its buildings over 1,000 m², against 42% across England and Wales.
  • More of its buildings are heated mainly by grid electricity (47%) than by gas (44%); across England and Wales gas leads, 53% to 37%.
  • In the 12 months to 30 Sep 2026, 18 industrial and warehouse buildings of any size here had an EPC lodged to be let and 8 for a marketed sale, 26 in all: the 25th most of 64 local authorities in the South East.
  • The recommendation lodged most often on its certificates rated C to G is “Consider replacing T8 lamps with retrofit T5 conversion kit” (EPC-L5), on 23 of 30 buildings.

Every rating, A+ to G

Canterbury's 43 industrial and warehouse buildings over 1,000 m² by latest EPC rating, beside the South East and the whole of England and Wales.

By latest EPC rating

Share is of buildings over 1,000 m² in each area.

Canterbury: industrial and warehouse buildings over 1,000 m² by latest EPC rating, with the share in each band and South East's and England and Wales's
RatingBuildingsFloor areaShareSouth EastEngland and Wales
A+00 sq ft0 m²0%3%2%
A4170k sq ft15,783 m²9%13%10%
B9309k sq ft28,718 m²21%22%19%
C16320k sq ft29,684 m²37%35%36%
D11188k sq ft17,492 m²26%21%22%
E252k sq ft4,812 m²5%6%9%
F113k sq ft1,176 m²2%1%1%
G00 sq ft0 m²0%1%2%

Within 10 points of B

Rated C with an asset rating of 51 to 60. Band B ends at 50.

5 buildings

Of 16 rated C (31%), with 93k sq ft (8,650 m²) of floorspace. England and Wales: 37% of C-rated buildings.

By building size

Floor area as declared on the EPC.

Canterbury: industrial and warehouse buildings by floor area
Floor areaBuildingsRated B or betterC to E floor area
Over 1,000 to 5,000 m²3923%9 of 39560k sq ft51,988 m²
Over 5,000 to 10,000 m²3100%3 of 30 sq ft0 m²
Over 10,000 m²1100%1 of 10 sq ft0 m²

Certificates and lettings

An EPC lasts 10 years, and a valid one is needed to let or sell. We estimate expiry as the lodgement date plus 10 years.

When the certificates lapse

Buildings over 1,000 m², by when their latest EPC lapses, at 30 Sep 2026.

Canterbury: when each building's latest EPC lapses (estimated)
EPC lapsesAll buildingsRated C to GC to G floor area
Already lapsed128160k sq ft14,883 m²
Rest of 2026000 sq ft0 m²
In 20272256k sq ft5,187 m²
In 20282234k sq ft3,132 m²
In 20291132k sq ft2,997 m²
In 20304458k sq ft5,429 m²
2031 or later2213232k sq ft21,536 m²

New EPCs in the last year

Industrial and warehouse buildings of any size whose latest EPC was lodged in the 12 months to 30 Sep 2026, by the reason on the certificate.

To let
18buildings
Marketed sale
8buildings
New build
0buildings
Other reasons
4buildings

30 in all: 60% to let, against 56% across England and Wales. How the daily feed works

Uses, heating and recommendations

What the buildings are used for, how they're heated, and what assessors recommended on the certificates of those rated C to G.

By use

Use from the EPC's property type.

Canterbury: buildings over 1,000 m² by use, from the EPC's property type
UseBuildingsB or betterC to EF or GC to E floor area
Storage and distribution (B8)198110207k sq ft19,185 m²
General industrial (B2)245181353k sq ft32,803 m²

By main heating fuel

As recorded on each building's latest EPC.

Canterbury: buildings over 1,000 m² by main heating fuel on the EPC
Main heating fuelBuildingsShareEngland and Wales
Grid supplied electricity2047%37%
Natural gas1944%53%
Other25%4%
LPG12%1%
Oil12%4%

What assessors recommend

The five most common on the latest certificates of its 30 buildings rated C to G, in the register's wording. A recommendation is the assessor's, not a requirement.

  1. 01

    Consider replacing T8 lamps with retrofit T5 conversion kit.

    EPC-L5. On 23 of 30 buildings (77%)

  2. 02

    Introduce HF (high frequency) ballasts for fluorescent tubes: Reduced number of fittings required.

    EPC-L7. On 22 of 30 buildings (73%)

  3. 03

    Add optimum start/stop to the heating system.

    EPC-H7. On 17 of 30 buildings (57%)

  4. 04

    In some spaces, the solar gain limit defined in the NCM is exceeded, which might cause overheating. Consider solar control measures such as the application of reflective coating or shading devices to windows.

    EPC-V1. On 17 of 30 buildings (57%)

  5. 05

    Consider installing building mounted wind turbine(s).

    EPC-R2. On 15 of 30 buildings (50%)

How Canterbury compares

Canterbury has less than 0.1% of the industrial floorspace rated C to E in England and Wales. 70% of its buildings over 1,000 m² are below B, against 63% across the South East, and the same as nationally.

Against the region and the country

Canterbury against the South East and England and Wales: industrial and warehouse buildings over 1,000 m²
AreaOver 1,000 m²Rated C to EC to E floor areaRated F or GShare below B
Canterbury4329560k sq ft51,988 m²170%
South East5,1193,153101.6m sq ft9,439,390 m²6663%
England and Wales38,14825,6191.01bn sq ft94,020,657 m²1,03770%

Nearby in the South East ranking

Local authorities ranked next to Canterbury in the South East by floorspace rated C to E
RankLocal authorityC to E floor area
51Oxford609k sq ft56,547 m²
52Isle of Wight603k sq ft55,989 m²
53Canterbury560k sq ft51,988 m²
54Brighton and Hove544k sq ft50,579 m²
55Runnymede521k sq ft48,404 m²

What the 2031 proposal means

In June 2026 the government said it intends that privately rented non-domestic buildings over 1,000 m² reach EPC B from 2031, where cost effective. It needs secondary legislation, so for now it's a proposal, not law. What the proposal means

  • C to E: fine today, short of B

    Canterbury has 29 buildings over 1,000 m² rated C to E. They meet today's E minimum, but would fall short of B if the proposal becomes law while they're let.
  • F or G: below the minimum already

    1 building in Canterbury is rated F or G. If let, it already needs an improvement or a registered exemption under today's rules.
  • Where cost effective, and only when let

    The 7-year payback test and the exemptions remain. Owner-occupied buildings are counted too, as an EPC can't say whether a building is let. Local weights and measures authorities enforce the rules. MEES in plain English
  • Ratings change at renewal

    17 of Canterbury's buildings rated C to G have an EPC that has lapsed or is estimated to lapse before 2031. Each needs a new certificate before it's let or sold, and the new rating may differ.

Go building by building

  • One building at a time

    Search by postcode or estate name for each industrial building's rating, floor area, certificate expiry and whether it's over 1,000 m². Free, and you can save five buildings to a free account.

    Check a building in Canterbury
  • The whole local authority

    Professional's area screens list every industrial building over 1,000 m² in a local authority with its rating and expiry, for 3 local authorities. £79 a month, or £790 a year.

    Compare plans

The Industrial EPC Weekly

Last week's new industrial EPCs by region, every Monday. Free.