Skip to content

East Midlands

MEES 2031 exposure in Gedling

42 of the 59 industrial and warehouse buildings over 1,000 m² in Gedling with an EPC are rated C to E: 1.5m sq ft (141,491 m²) of floorspace that meets today's E minimum but falls short of the proposed EPC B standard.

Free. No card needed.

Gedling in figures

EPC register, snapshot 30 Sep 2026

Rated C to E
1.5m sq ft141,491 m² in 42 buildings
Rated F or G
2 buildings45k sq ft (4,170 m²), below today's E minimum
Rated A+ to B
15 buildingsAlready at the proposed standard
Share below B
75%Of 59 buildings over 1,000 m². England and Wales: 70%

Gedling has the 196th most floorspace rated C to E of 316 local authorities in England and Wales, and the 25th most of 35 in the East Midlands.

EPC rating mix

Share of buildings over 1,000 m², by latest EPC rating

  • Gedling59 buildings
  • East Midlands4,027 buildings
  • England and Wales38,148 buildings
Key: Rated A+–B: At B or better alreadyRated C–E: Meets today's E minimum, short of BRated F–G: Below today's E minimum

Latest certificate per building from the government's EPC register, snapshot 30 Sep 2026. Industrial and warehouse uses (B2 and B8), floor area over 1,000 m² as declared on the EPC; 1 m² is 10.7639 sq ft. How we count it

What stands out in Gedling

Compared with the other 34 local authorities in the East Midlands and with England and Wales, from the same EPC register snapshot.

  • Most of its floorspace rated C to E, 55% or 831k sq ft (77,211 m²), is in 35 buildings of 1,000 to 5,000 m².
  • 26 of its 44 buildings rated C to G (59%) have an EPC that has lapsed or is estimated to lapse before 2031, against 54% across England and Wales; 12 have already lapsed.
  • 10 of its 24 C-rated buildings (42%) have an asset rating of 51 to 60, within 10 points of band B: 321k sq ft (29,855 m²) of floorspace. Across England and Wales it's 37%.
  • General industrial (B2) makes up 61% of its buildings over 1,000 m², against 42% across England and Wales.
  • In the 12 months to 30 Sep 2026, 6 industrial and warehouse buildings of any size here had an EPC lodged to be let and 3 for a marketed sale, 9 in all: the 3rd fewest of 35 local authorities in the East Midlands.
  • Two recommendations are joint most common on its certificates rated C to G, each on 27 of 44 buildings: “Consider replacing T8 lamps with retrofit T5 conversion kit” (EPC-L5) and “In some spaces, the solar gain limit defined in the NCM is exceeded, which might cause overheating. Consider solar control measures such as the application of reflective coating or shading devices to windows” (EPC-V1).

Every rating, A+ to G

Gedling's 59 industrial and warehouse buildings over 1,000 m² by latest EPC rating, beside the East Midlands and the whole of England and Wales.

By latest EPC rating

Share is of buildings over 1,000 m² in each area.

Gedling: industrial and warehouse buildings over 1,000 m² by latest EPC rating, with the share in each band and East Midlands's and England and Wales's
RatingBuildingsFloor areaShareEast MidlandsEngland and Wales
A+00 sq ft0 m²0%1%2%
A00 sq ft0 m²0%10%10%
B15615k sq ft57,098 m²25%18%19%
C24999k sq ft92,834 m²41%35%36%
D17493k sq ft45,815 m²29%24%22%
E131k sq ft2,842 m²2%9%9%
F126k sq ft2,435 m²2%1%1%
G119k sq ft1,735 m²2%2%2%

Within 10 points of B

Rated C with an asset rating of 51 to 60. Band B ends at 50.

10 buildings

Of 24 rated C (42%), with 321k sq ft (29,855 m²) of floorspace. England and Wales: 37% of C-rated buildings.

By building size

Floor area as declared on the EPC.

Gedling: industrial and warehouse buildings by floor area
Floor areaBuildingsRated B or betterC to E floor area
Over 1,000 to 5,000 m²4924%12 of 49831k sq ft77,211 m²
Over 5,000 to 10,000 m²60%0 of 6456k sq ft42,341 m²
Over 10,000 m²475%3 of 4236k sq ft21,939 m²

Certificates and lettings

An EPC lasts 10 years, and a valid one is needed to let or sell. We estimate expiry as the lodgement date plus 10 years.

When the certificates lapse

Buildings over 1,000 m², by when their latest EPC lapses, at 30 Sep 2026.

Gedling: when each building's latest EPC lapses (estimated)
EPC lapsesAll buildingsRated C to GC to G floor area
Already lapsed1212251k sq ft23,356 m²
Rest of 2026000 sq ft0 m²
In 202722139k sq ft12,868 m²
In 202854139k sq ft12,922 m²
In 202933117k sq ft10,845 m²
In 203055182k sq ft16,879 m²
2031 or later3218740k sq ft68,791 m²

New EPCs in the last year

Industrial and warehouse buildings of any size whose latest EPC was lodged in the 12 months to 30 Sep 2026, by the reason on the certificate.

To let
6buildings
Marketed sale
3buildings
New build
0buildings
Other reasons
0buildings

9 in all: 67% to let, against 56% across England and Wales. How the daily feed works

Uses, heating and recommendations

What the buildings are used for, how they're heated, and what assessors recommended on the certificates of those rated C to G.

By use

Use from the EPC's property type.

Gedling: buildings over 1,000 m² by use, from the EPC's property type
UseBuildingsB or betterC to EF or GC to E floor area
Storage and distribution (B8)237160527k sq ft48,969 m²
General industrial (B2)368262996k sq ft92,522 m²

By main heating fuel

As recorded on each building's latest EPC.

Gedling: buildings over 1,000 m² by main heating fuel on the EPC
Main heating fuelBuildingsShareEngland and Wales
Natural gas3153%53%
Grid supplied electricity2237%37%
Other47%4%
Oil23%4%

What assessors recommend

The five most common on the latest certificates of its 44 buildings rated C to G, in the register's wording. A recommendation is the assessor's, not a requirement.

  1. 01

    Consider replacing T8 lamps with retrofit T5 conversion kit.

    EPC-L5. On 27 of 44 buildings (61%)

  2. 02

    In some spaces, the solar gain limit defined in the NCM is exceeded, which might cause overheating. Consider solar control measures such as the application of reflective coating or shading devices to windows.

    EPC-V1. On 27 of 44 buildings (61%)

  3. 03

    Add optimum start/stop to the heating system.

    EPC-H7. On 25 of 44 buildings (57%)

  4. 04

    Carry out a pressure test, identify and treat identified air leakage. Enter result in EPC calculation.

    EPC-E7. On 24 of 44 buildings (55%)

  5. 05

    Consider installing PV.

    EPC-R4. On 24 of 44 buildings (55%)

How Gedling compares

Gedling has 0.2% of the industrial floorspace rated C to E in England and Wales. 75% of its buildings over 1,000 m² are below B, against 71% across the East Midlands and 70% nationally.

Against the region and the country

Gedling against the East Midlands and England and Wales: industrial and warehouse buildings over 1,000 m²
AreaOver 1,000 m²Rated C to EC to E floor areaRated F or GShare below B
Gedling59421.5m sq ft141,491 m²275%
East Midlands4,0272,740130.2m sq ft12,092,961 m²12471%
England and Wales38,14825,6191.01bn sq ft94,020,657 m²1,03770%

Nearby in the East Midlands ranking

Local authorities ranked next to Gedling in the East Midlands by floorspace rated C to E
RankLocal authorityC to E floor area
23East Lindsey1.6m sq ft151,108 m²
24West Lindsey1.5m sq ft143,356 m²
25Gedling1.5m sq ft141,491 m²
26Melton1.4m sq ft134,063 m²
27Broxtowe1.4m sq ft133,626 m²

What the 2031 proposal means

In June 2026 the government said it intends that privately rented non-domestic buildings over 1,000 m² reach EPC B from 2031, where cost effective. It needs secondary legislation, so for now it's a proposal, not law. What the proposal means

  • C to E: fine today, short of B

    Gedling has 42 buildings over 1,000 m² rated C to E. They meet today's E minimum, but would fall short of B if the proposal becomes law while they're let.
  • F or G: below the minimum already

    2 buildings in Gedling are rated F or G. If let, they already need an improvement or a registered exemption under today's rules.
  • Where cost effective, and only when let

    The 7-year payback test and the exemptions remain. Owner-occupied buildings are counted too, as an EPC can't say whether a building is let. Local weights and measures authorities enforce the rules. MEES in plain English
  • Ratings change at renewal

    26 of Gedling's buildings rated C to G have an EPC that has lapsed or is estimated to lapse before 2031. Each needs a new certificate before it's let or sold, and the new rating may differ.

Go building by building

  • One building at a time

    Search by postcode or estate name for each industrial building's rating, floor area, certificate expiry and whether it's over 1,000 m². Free, and you can save five buildings to a free account.

    Check a building in Gedling
  • The whole local authority

    Professional's area screens list every industrial building over 1,000 m² in a local authority with its rating and expiry, for 3 local authorities. £79 a month, or £790 a year.

    Compare plans

The Industrial EPC Weekly