MEES 2031 exposure in Mansfield

36 of the 55 industrial and warehouse buildings over 1,000 m² in Mansfield with an EPC are rated C to E: 1.4m sq ft (126,646 m²) of floorspace that meets today's E minimum but falls short of the proposed EPC B standard.

Free. No card needed.

Mansfield in figures

EPC register, snapshot 30 Sep 2026

Rated C to E
1.4m sq ft126,646 m² in 36 buildings
Rated F or G
1 building17k sq ft (1,621 m²), below today's E minimum
Rated A+ to B
18 buildingsAlready at the proposed standard
Share below B
67%Of 55 buildings over 1,000 m². England and Wales: 70%

Mansfield has the 215th most floorspace rated C to E of 316 local authorities in England and Wales, and the 29th most of 35 in the East Midlands.

EPC rating mix

Share of buildings over 1,000 m², by latest EPC rating

  • Mansfield55 buildings
  • East Midlands4,027 buildings
  • England and Wales38,148 buildings
Key: Rated A+–B: At B or better alreadyRated C–E: Meets today's E minimum, short of BRated F–G: Below today's E minimum

Latest certificate per building from the government's EPC register, snapshot 30 Sep 2026. Industrial and warehouse uses (B2 and B8), floor area over 1,000 m² as declared on the EPC; 1 m² is 10.7639 sq ft. How we count it

What stands out in Mansfield

Compared with the other 34 local authorities in the East Midlands and with England and Wales, from the same EPC register snapshot.

  • Its floorspace rated C to E is spread across sizes: 44% in buildings of 1,000 to 5,000 m², 39% in buildings of 5,000 to 10,000 m², 17% in buildings over 10,000 m².
  • 15 of its 37 buildings rated C to G (41%) have an EPC that has lapsed or is estimated to lapse before 2031, against 54% across England and Wales; 11 have already lapsed.
  • 2 of its 22 C-rated buildings (9%) have an asset rating of 51 to 60, within 10 points of band B: 137k sq ft (12,772 m²) of floorspace. Across England and Wales it's 37%.
  • General industrial (B2) makes up 58% of its buildings over 1,000 m², against 42% across England and Wales.
  • In the 12 months to 30 Sep 2026, 9 industrial and warehouse buildings of any size here had an EPC lodged to be let and 10 for a marketed sale, 19 in all: the 16th fewest of 35 local authorities in the East Midlands.
  • Two recommendations are joint most common on its certificates rated C to G, each on 24 of 37 buildings: “Carry out a pressure test, identify and treat identified air leakage. Enter result in EPC calculation” (EPC-E7) and “Consider installing building mounted wind turbine(s)” (EPC-R2).

Every rating, A+ to G

Mansfield's 55 industrial and warehouse buildings over 1,000 m² by latest EPC rating, beside the East Midlands and the whole of England and Wales.

By latest EPC rating

Share is of buildings over 1,000 m² in each area.

Mansfield: industrial and warehouse buildings over 1,000 m² by latest EPC rating, with the share in each band and East Midlands's and England and Wales's
RatingBuildingsFloor areaShareEast MidlandsEngland and Wales
A+1103k sq ft9,566 m²2%1%2%
A2129k sq ft12,029 m²4%10%10%
B15643k sq ft59,746 m²27%18%19%
C22835k sq ft77,610 m²40%35%36%
D12413k sq ft38,332 m²22%24%22%
E2115k sq ft10,704 m²4%9%9%
F117k sq ft1,621 m²2%1%1%
G00 sq ft0 m²0%2%2%

Within 10 points of B

Rated C with an asset rating of 51 to 60. Band B ends at 50.

2 buildings

Of 22 rated C (9%), with 137k sq ft (12,772 m²) of floorspace. England and Wales: 37% of C-rated buildings.

By building size

Floor area as declared on the EPC.

Mansfield: industrial and warehouse buildings by floor area
Floor areaBuildingsRated B or betterC to E floor area
Over 1,000 to 5,000 m²4129%12 of 41604k sq ft56,098 m²
Over 5,000 to 10,000 m²1145%5 of 11526k sq ft48,898 m²
Over 10,000 m²333%1 of 3233k sq ft21,650 m²

Certificates and lettings

An EPC lasts 10 years, and a valid one is needed to let or sell. We estimate expiry as the lodgement date plus 10 years.

When the certificates lapse

Buildings over 1,000 m², by when their latest EPC lapses, at 30 Sep 2026.

Mansfield: when each building's latest EPC lapses (estimated)
EPC lapsesAll buildingsRated C to GC to G floor area
Already lapsed1311250k sq ft23,230 m²
Rest of 2026000 sq ft0 m²
In 2027000 sq ft0 m²
In 2028100 sq ft0 m²
In 20293137k sq ft3,475 m²
In 203043122k sq ft11,312 m²
2031 or later3422971k sq ft90,250 m²

New EPCs in the last year

Industrial and warehouse buildings of any size whose latest EPC was lodged in the 12 months to 30 Sep 2026, by the reason on the certificate.

To let
9buildings
Marketed sale
10buildings
New build
1building
Other reasons
5buildings

25 in all: 36% to let, against 56% across England and Wales. How the daily feed works

Uses, heating and recommendations

What the buildings are used for, how they're heated, and what assessors recommended on the certificates of those rated C to G.

By use

Use from the EPC's property type.

Mansfield: buildings over 1,000 m² by use, from the EPC's property type
UseBuildingsB or betterC to EF or GC to E floor area
Storage and distribution (B8)235171829k sq ft77,060 m²
General industrial (B2)3213190534k sq ft49,586 m²

By main heating fuel

As recorded on each building's latest EPC.

Mansfield: buildings over 1,000 m² by main heating fuel on the EPC
Main heating fuelBuildingsShareEngland and Wales
Natural gas3462%53%
Grid supplied electricity1425%37%
Biomass47%1%
Other35%4%

What assessors recommend

The five most common on the latest certificates of its 37 buildings rated C to G, in the register's wording. A recommendation is the assessor's, not a requirement.

  1. 01

    Carry out a pressure test, identify and treat identified air leakage. Enter result in EPC calculation.

    EPC-E7. On 24 of 37 buildings (65%)

  2. 02

    Consider installing building mounted wind turbine(s).

    EPC-R2. On 24 of 37 buildings (65%)

  3. 03

    Consider installing PV.

    EPC-R4. On 23 of 37 buildings (62%)

  4. 04

    Add weather compensation controls to heating system.

    EPC-H8. On 21 of 37 buildings (57%)

  5. 05

    Consider replacing T8 lamps with retrofit T5 conversion kit.

    EPC-L5. On 21 of 37 buildings (57%)

How Mansfield compares

Mansfield has 0.1% of the industrial floorspace rated C to E in England and Wales. 67% of its buildings over 1,000 m² are below B, against 71% across the East Midlands and 70% nationally.

Against the region and the country

Mansfield against the East Midlands and England and Wales: industrial and warehouse buildings over 1,000 m²
AreaOver 1,000 m²Rated C to EC to E floor areaRated F or GShare below B
Mansfield55361.4m sq ft126,646 m²167%
East Midlands4,0272,740130.2m sq ft12,092,961 m²12471%
England and Wales38,14825,6191.01bn sq ft94,020,657 m²1,03770%

Nearby in the East Midlands ranking

Local authorities ranked next to Mansfield in the East Midlands by floorspace rated C to E
RankLocal authorityC to E floor area
27Broxtowe1.4m sq ft133,626 m²
28North East Derbyshire1.4m sq ft129,939 m²
29Mansfield1.4m sq ft126,646 m²
30North Kesteven1.3m sq ft123,986 m²
31Oadby and Wigston920k sq ft85,466 m²

What the 2031 proposal means

In June 2026 the government said it intends that privately rented non-domestic buildings over 1,000 m² reach EPC B from 2031, where cost effective. It needs secondary legislation, so for now it's a proposal, not law. What the proposal means

  • C to E: fine today, short of B

    Mansfield has 36 buildings over 1,000 m² rated C to E. They meet today's E minimum, but would fall short of B if the proposal becomes law while they're let.
  • F or G: below the minimum already

    1 building in Mansfield is rated F or G. If let, it already needs an improvement or a registered exemption under today's rules.
  • Where cost effective, and only when let

    The 7-year payback test and the exemptions remain. Owner-occupied buildings are counted too, as an EPC can't say whether a building is let. Local weights and measures authorities enforce the rules. MEES in plain English
  • Ratings change at renewal

    15 of Mansfield's buildings rated C to G have an EPC that has lapsed or is estimated to lapse before 2031. Each needs a new certificate before it's let or sold, and the new rating may differ.

Go building by building

  • One building at a time

    Search by postcode or estate name for each industrial building's rating, floor area, certificate expiry and whether it's over 1,000 m². Free, and you can save five buildings to a free account.

    Check a building in Mansfield
  • The whole local authority

    Professional's area screens list every industrial building over 1,000 m² in a local authority with its rating and expiry, for 3 local authorities. £79 a month, or £790 a year.

    Compare plans

The Industrial EPC Weekly

Last week's new industrial EPCs by region, every Monday. Free.