Skip to content

North West

MEES 2031 exposure in South Ribble

70 of the 114 industrial and warehouse buildings over 1,000 m² in South Ribble with an EPC are rated C to E: 1.9m sq ft (181,073 m²) of floorspace that meets today's E minimum but falls short of the proposed EPC B standard.

Free. No card needed.

South Ribble in figures

EPC register, snapshot 30 Sep 2026

Rated C to E
1.9m sq ft181,073 m² in 70 buildings
Rated F or G
10 buildings284k sq ft (26,361 m²), below today's E minimum
Rated A+ to B
34 buildingsAlready at the proposed standard
Share below B
70%Of 114 buildings over 1,000 m². England and Wales: 70%

South Ribble has the 172nd most floorspace rated C to E of 316 local authorities in England and Wales, and the 30th most of 35 in the North West.

EPC rating mix

Share of buildings over 1,000 m², by latest EPC rating

  • South Ribble114 buildings
  • North West5,313 buildings
  • England and Wales38,148 buildings
Key: Rated A+–B: At B or better alreadyRated C–E: Meets today's E minimum, short of BRated F–G: Below today's E minimum

Latest certificate per building from the government's EPC register, snapshot 30 Sep 2026. Industrial and warehouse uses (B2 and B8), floor area over 1,000 m² as declared on the EPC; 1 m² is 10.7639 sq ft. How we count it

What stands out in South Ribble

Compared with the other 34 local authorities in the North West and with England and Wales, from the same EPC register snapshot.

  • South Ribble has a higher share of buildings rated F or G (9%) than any other local authority in the North West, against 3% across England and Wales.
  • Most of its floorspace rated C to E, 68% or 1.3m sq ft (122,901 m²), is in 62 buildings of 1,000 to 5,000 m².
  • Its largest buildings are likelier to meet B: 100% of the 6 over 10,000 m² are rated B or better, against 28% of those of 1,000 to 5,000 m².
  • 39 of its 80 buildings rated C to G (49%) have an EPC that has lapsed or is estimated to lapse before 2031, against 54% across England and Wales; 21 have already lapsed.
  • 15 of its 37 C-rated buildings (41%) have an asset rating of 51 to 60, within 10 points of band B: 351k sq ft (32,623 m²) of floorspace. Across England and Wales it's 37%.
  • Its storage and distribution buildings are likelier to meet B (35%) than its general industrial ones (24%).
  • Gas is the main heating fuel in 64% of its buildings, against 53% across England and Wales.
  • In the 12 months to 30 Sep 2026, 37 industrial and warehouse buildings of any size here had an EPC lodged to be let and 3 for a marketed sale, 40 in all: the 16th most of 35 local authorities in the North West.
  • The recommendation lodged most often on its certificates rated C to G is “Consider replacing T8 lamps with retrofit T5 conversion kit” (EPC-L5), on 60 of 80 buildings.

Every rating, A+ to G

South Ribble's 114 industrial and warehouse buildings over 1,000 m² by latest EPC rating, beside the North West and the whole of England and Wales.

By latest EPC rating

Share is of buildings over 1,000 m² in each area.

South Ribble: industrial and warehouse buildings over 1,000 m² by latest EPC rating, with the share in each band and North West's and England and Wales's
RatingBuildingsFloor areaShareNorth WestEngland and Wales
A+00 sq ft0 m²0%1%2%
A91.3m sq ft122,262 m²8%9%10%
B251.3m sq ft118,668 m²22%18%19%
C37933k sq ft86,691 m²32%37%36%
D23672k sq ft62,410 m²20%22%22%
E10344k sq ft31,972 m²9%10%9%
F00 sq ft0 m²0%1%1%
G10284k sq ft26,361 m²9%2%2%

Within 10 points of B

Rated C with an asset rating of 51 to 60. Band B ends at 50.

15 buildings

Of 37 rated C (41%), with 351k sq ft (32,623 m²) of floorspace. England and Wales: 37% of C-rated buildings.

By building size

Floor area as declared on the EPC.

South Ribble: industrial and warehouse buildings by floor area
Floor areaBuildingsRated B or betterC to E floor area
Over 1,000 to 5,000 m²9828%27 of 981.3m sq ft122,901 m²
Over 5,000 to 10,000 m²1010%1 of 10626k sq ft58,172 m²
Over 10,000 m²6100%6 of 60 sq ft0 m²

Certificates and lettings

An EPC lasts 10 years, and a valid one is needed to let or sell. We estimate expiry as the lodgement date plus 10 years.

When the certificates lapse

Buildings over 1,000 m², by when their latest EPC lapses, at 30 Sep 2026.

South Ribble: when each building's latest EPC lapses (estimated)
EPC lapsesAll buildingsRated C to GC to G floor area
Already lapsed2521543k sq ft50,436 m²
Rest of 20261113k sq ft1,191 m²
In 20273361k sq ft5,672 m²
In 202888285k sq ft26,461 m²
In 20294248k sq ft4,478 m²
In 20304479k sq ft7,328 m²
2031 or later69411.2m sq ft111,868 m²

New EPCs in the last year

Industrial and warehouse buildings of any size whose latest EPC was lodged in the 12 months to 30 Sep 2026, by the reason on the certificate.

To let
37buildings
Marketed sale
3buildings
New build
0buildings
Other reasons
4buildings

44 in all: 84% to let, against 56% across England and Wales. How the daily feed works

Uses, heating and recommendations

What the buildings are used for, how they're heated, and what assessors recommended on the certificates of those rated C to G.

By use

Use from the EPC's property type.

South Ribble: buildings over 1,000 m² by use, from the EPC's property type
UseBuildingsB or betterC to EF or GC to E floor area
Storage and distribution (B8)6322347939k sq ft87,277 m²
General industrial (B2)51123631.0m sq ft93,796 m²

By main heating fuel

As recorded on each building's latest EPC.

South Ribble: buildings over 1,000 m² by main heating fuel on the EPC
Main heating fuelBuildingsShareEngland and Wales
Natural gas7364%53%
Grid supplied electricity2825%37%
Other76%4%
Oil65%4%

What assessors recommend

The five most common on the latest certificates of its 80 buildings rated C to G, in the register's wording. A recommendation is the assessor's, not a requirement.

  1. 01

    Consider replacing T8 lamps with retrofit T5 conversion kit.

    EPC-L5. On 60 of 80 buildings (75%)

  2. 02

    Introduce HF (high frequency) ballasts for fluorescent tubes: Reduced number of fittings required.

    EPC-L7. On 53 of 80 buildings (66%)

  3. 03

    Add optimum start/stop to the heating system.

    EPC-H7. On 46 of 80 buildings (57%)

  4. 04

    Consider installing building mounted wind turbine(s).

    EPC-R2. On 46 of 80 buildings (57%)

  5. 05

    Consider installing solar water heating.

    EPC-R3. On 46 of 80 buildings (57%)

How South Ribble compares

South Ribble has 0.2% of the industrial floorspace rated C to E in England and Wales. 70% of its buildings over 1,000 m² are below B, against 72% across the North West, and the same as nationally.

Against the region and the country

South Ribble against the North West and England and Wales: industrial and warehouse buildings over 1,000 m²
AreaOver 1,000 m²Rated C to EC to E floor areaRated F or GShare below B
South Ribble114701.9m sq ft181,073 m²1070%
North West5,3133,674160.1m sq ft14,878,125 m²16372%
England and Wales38,14825,6191.01bn sq ft94,020,657 m²1,03770%

Nearby in the North West ranking

Local authorities ranked next to South Ribble in the North West by floorspace rated C to E
RankLocal authorityC to E floor area
28Sefton2.2m sq ft203,531 m²
29Chorley2.2m sq ft199,934 m²
30South Ribble1.9m sq ft181,073 m²
31Lancaster1.5m sq ft136,760 m²
32Rossendale1.5m sq ft135,041 m²

What the 2031 proposal means

In June 2026 the government said it intends that privately rented non-domestic buildings over 1,000 m² reach EPC B from 2031, where cost effective. It needs secondary legislation, so for now it's a proposal, not law. What the proposal means

  • C to E: fine today, short of B

    South Ribble has 70 buildings over 1,000 m² rated C to E. They meet today's E minimum, but would fall short of B if the proposal becomes law while they're let.
  • F or G: below the minimum already

    10 buildings in South Ribble are rated F or G. If let, they already need an improvement or a registered exemption under today's rules.
  • Where cost effective, and only when let

    The 7-year payback test and the exemptions remain. Owner-occupied buildings are counted too, as an EPC can't say whether a building is let. Local weights and measures authorities enforce the rules. MEES in plain English
  • Ratings change at renewal

    39 of South Ribble's buildings rated C to G have an EPC that has lapsed or is estimated to lapse before 2031. Each needs a new certificate before it's let or sold, and the new rating may differ.

Go building by building

  • One building at a time

    Search by postcode or estate name for each industrial building's rating, floor area, certificate expiry and whether it's over 1,000 m². Free, and you can save five buildings to a free account.

    Check a building in South Ribble
  • The whole local authority

    Professional's area screens list every industrial building over 1,000 m² in a local authority with its rating and expiry, for 3 local authorities. £79 a month, or £790 a year.

    Compare plans

The Industrial EPC Weekly

Last week's new industrial EPCs by region, every Monday. Free.