North West
MEES 2031 exposure in West Lancashire
95 of the 128 industrial and warehouse buildings over 1,000 m² in West Lancashire with an EPC are rated C to E: 5.6m sq ft (519,544 m²) of floorspace that meets today's E minimum but falls short of the proposed EPC B standard.
Free. No card needed.
West Lancashire in figures
EPC register, snapshot 30 Sep 2026
- Rated C to E
- 5.6m sq ft519,544 m² in 95 buildings
- Rated F or G
- 2 buildings39k sq ft (3,639 m²), below today's E minimum
- Rated A+ to B
- 31 buildingsAlready at the proposed standard
- Share below B
- 76%Of 128 buildings over 1,000 m². England and Wales: 70%
West Lancashire has the 53rd most floorspace rated C to E of 316 local authorities in England and Wales, and the 14th most of 35 in the North West.
EPC rating mix
Share of buildings over 1,000 m², by latest EPC rating
- West Lancashire128 buildings24%74%
- North West5,313 buildings28%69%
- England and Wales38,148 buildings30%67%
Latest certificate per building from the government's EPC register, snapshot 30 Sep 2026. Industrial and warehouse uses (B2 and B8), floor area over 1,000 m² as declared on the EPC; 1 m² is 10.7639 sq ft. How we count it
What stands out in West Lancashire
Compared with the other 34 local authorities in the North West and with England and Wales, from the same EPC register snapshot.
- Most of its floorspace rated C to E, 54% or 3.0m sq ft (282,775 m²), is in 15 buildings over 10,000 m².
- Unusually, its smaller buildings do better: 22% of those of 1,000 to 5,000 m² are rated B or better, against 17% of the 18 over 10,000 m².
- 60 of its 97 buildings rated C to G (62%) have an EPC that has lapsed or is estimated to lapse before 2031, against 54% across England and Wales; 30 have already lapsed.
- 20 of its 50 C-rated buildings (40%) have an asset rating of 51 to 60, within 10 points of band B: 1.4m sq ft (127,447 m²) of floorspace. Across England and Wales it's 37%.
- 13% of its buildings are heated mainly by oil, LPG or biomass, against 6% across England and Wales.
- In the 12 months to 30 Sep 2026, 18 industrial and warehouse buildings of any size here had an EPC lodged to be let and 4 for a marketed sale, 22 in all: the 10th fewest of 35 local authorities in the North West.
- The recommendation lodged most often on its certificates rated C to G is “Consider installing building mounted wind turbine(s)” (EPC-R2), on 66 of 97 buildings.
Every rating, A+ to G
West Lancashire's 128 industrial and warehouse buildings over 1,000 m² by latest EPC rating, beside the North West and the whole of England and Wales.
By latest EPC rating
Share is of buildings over 1,000 m² in each area.
| Rating | Buildings | Floor area | Share | North West | England and Wales |
|---|---|---|---|---|---|
| A+ | 0 | 0 sq ft0 m² | 0% | 1% | 2% |
| A | 10 | 772k sq ft71,763 m² | 8% | 9% | 10% |
| B | 21 | 1.7m sq ft153,623 m² | 16% | 18% | 19% |
| C | 50 | 3.4m sq ft314,118 m² | 39% | 37% | 36% |
| D | 31 | 1.7m sq ft154,936 m² | 24% | 22% | 22% |
| E | 14 | 543k sq ft50,490 m² | 11% | 10% | 9% |
| F | 1 | 19k sq ft1,743 m² | 1% | 1% | 1% |
| G | 1 | 20k sq ft1,896 m² | 1% | 2% | 2% |
Within 10 points of B
Rated C with an asset rating of 51 to 60. Band B ends at 50.
20 buildings
Of 50 rated C (40%), with 1.4m sq ft (127,447 m²) of floorspace. England and Wales: 37% of C-rated buildings.
By building size
Floor area as declared on the EPC.
| Floor area | Buildings | Rated B or better | C to E floor area |
|---|---|---|---|
| Over 1,000 to 5,000 m² | 89 | 22%20 of 89 | 1.5m sq ft137,543 m² |
| Over 5,000 to 10,000 m² | 21 | 38%8 of 21 | 1.1m sq ft99,226 m² |
| Over 10,000 m² | 18 | 17%3 of 18 | 3.0m sq ft282,775 m² |
Certificates and lettings
An EPC lasts 10 years, and a valid one is needed to let or sell. We estimate expiry as the lodgement date plus 10 years.
When the certificates lapse
Buildings over 1,000 m², by when their latest EPC lapses, at 30 Sep 2026.
| EPC lapses | All buildings | Rated C to G | C to G floor area |
|---|---|---|---|
| Already lapsed | 33 | 30 | 1.8m sq ft164,772 m² |
| Rest of 2026 | 2 | 2 | 93k sq ft8,665 m² |
| In 2027 | 9 | 9 | 938k sq ft87,098 m² |
| In 2028 | 8 | 6 | 233k sq ft21,640 m² |
| In 2029 | 6 | 6 | 187k sq ft17,341 m² |
| In 2030 | 8 | 7 | 149k sq ft13,868 m² |
| 2031 or later | 62 | 37 | 2.3m sq ft209,799 m² |
New EPCs in the last year
Industrial and warehouse buildings of any size whose latest EPC was lodged in the 12 months to 30 Sep 2026, by the reason on the certificate.
- To let
- 18buildings
- Marketed sale
- 4buildings
- New build
- 2buildings
- Other reasons
- 3buildings
27 in all: 67% to let, against 56% across England and Wales. How the daily feed works
Uses, heating and recommendations
What the buildings are used for, how they're heated, and what assessors recommended on the certificates of those rated C to G.
By use
Use from the EPC's property type.
| Use | Buildings | B or better | C to E | F or G | C to E floor area |
|---|---|---|---|---|---|
| Storage and distribution (B8) | 67 | 18 | 48 | 1 | 3.3m sq ft310,240 m² |
| General industrial (B2) | 61 | 13 | 47 | 1 | 2.3m sq ft209,304 m² |
By main heating fuel
As recorded on each building's latest EPC.
| Main heating fuel | Buildings | Share | England and Wales |
|---|---|---|---|
| Natural gas | 63 | 49% | 53% |
| Grid supplied electricity | 39 | 30% | 37% |
| Oil | 11 | 9% | 4% |
| Other | 9 | 7% | 4% |
| Biomass | 3 | 2% | 1% |
| LPG | 3 | 2% | 1% |
What assessors recommend
The five most common on the latest certificates of its 97 buildings rated C to G, in the register's wording. A recommendation is the assessor's, not a requirement.
- 01
Consider installing building mounted wind turbine(s).
EPC-R2. On 66 of 97 buildings (68%)
- 02
Consider replacing T8 lamps with retrofit T5 conversion kit.
EPC-L5. On 63 of 97 buildings (65%)
- 03
Consider installing solar water heating.
EPC-R3. On 58 of 97 buildings (60%)
- 04
Add optimum start/stop to the heating system.
EPC-H7. On 53 of 97 buildings (55%)
- 05
In some spaces, the solar gain limit defined in the NCM is exceeded, which might cause overheating. Consider solar control measures such as the application of reflective coating or shading devices to windows.
EPC-V1. On 53 of 97 buildings (55%)
How West Lancashire compares
West Lancashire has 0.6% of the industrial floorspace rated C to E in England and Wales. 76% of its buildings over 1,000 m² are below B, against 72% across the North West and 70% nationally.
Against the region and the country
| Area | Over 1,000 m² | Rated C to E | C to E floor area | Rated F or G | Share below B |
|---|---|---|---|---|---|
| West Lancashire | 128 | 95 | 5.6m sq ft519,544 m² | 2 | 76% |
| North West | 5,313 | 3,674 | 160.1m sq ft14,878,125 m² | 163 | 72% |
| England and Wales | 38,148 | 25,619 | 1.01bn sq ft94,020,657 m² | 1,037 | 70% |
Nearby in the North West ranking
| Rank | Local authority | C to E floor area |
|---|---|---|
| 12 | Knowsley | 6.0m sq ft561,656 m² |
| 13 | Liverpool | 5.6m sq ft519,908 m² |
| 14 | West Lancashire | 5.6m sq ft519,544 m² |
| 15 | Tameside | 5.3m sq ft496,776 m² |
| 16 | Halton | 4.5m sq ft420,270 m² |
What the 2031 proposal means
In June 2026 the government said it intends that privately rented non-domestic buildings over 1,000 m² reach EPC B from 2031, where cost effective. It needs secondary legislation, so for now it's a proposal, not law. What the proposal means
C to E: fine today, short of B
West Lancashire has 95 buildings over 1,000 m² rated C to E. They meet today's E minimum, but would fall short of B if the proposal becomes law while they're let.F or G: below the minimum already
2 buildings in West Lancashire are rated F or G. If let, they already need an improvement or a registered exemption under today's rules.Where cost effective, and only when let
The 7-year payback test and the exemptions remain. Owner-occupied buildings are counted too, as an EPC can't say whether a building is let. Local weights and measures authorities enforce the rules. MEES in plain EnglishRatings change at renewal
60 of West Lancashire's buildings rated C to G have an EPC that has lapsed or is estimated to lapse before 2031. Each needs a new certificate before it's let or sold, and the new rating may differ.
Go building by building
One building at a time
Search by postcode or estate name for each industrial building's rating, floor area, certificate expiry and whether it's over 1,000 m². Free, and you can save five buildings to a free account.
Check a building in West LancashireThe whole local authority
Professional's area screens list every industrial building over 1,000 m² in a local authority with its rating and expiry, for 3 local authorities. £79 a month, or £790 a year.
Compare plans